Steps to Replace Bypass Valve on Kenmore Water Softener

Water Softeners are essential appliances in many households, as they help to remove Minerals such as calcium and magnesium from the water supply. Over time, parts of the water softener may wear out or become damaged, requiring replacement. One common part that may need to be replaced is the bypass valve on a Kenmore water softener. In this article, we will discuss the steps involved in replacing the bypass valve on a Kenmore water softener.

The first step in replacing the bypass valve on a Kenmore water softener is to gather the necessary tools and materials. You will need a replacement bypass valve, a Wrench, and Teflon tape. It is important to ensure that the replacement bypass valve is compatible with your specific model of Kenmore water softener.

Once you have gathered the necessary tools and materials, the next step is to shut off the water supply to the water softener. This can usually be done by turning off the main water supply valve to the house. It is important to ensure that the water supply is completely shut off before proceeding with the replacement of the bypass valve.

After shutting off the water supply, the next step is to relieve the pressure in the water softener system. This can be done by opening a faucet in the house and allowing any remaining water in the system to drain out. Once the pressure has been relieved, you can proceed with removing the old bypass valve.

To remove the old bypass valve, you will need to use a wrench to loosen the fittings that connect the valve to the water softener. It is important to be careful when removing the fittings, as they may be tight and difficult to loosen. Once the fittings have been removed, you can then remove the old bypass valve from the water softener.

alt-498

After removing the old bypass valve, the next step is to install the replacement bypass valve. Before installing the new valve, it is a good idea to wrap the threads of the fittings with Teflon tape to ensure a tight seal. Once the Teflon tape has been applied, you can then install the replacement bypass valve and tighten the fittings with a wrench.

Once the replacement bypass valve has been installed and the fittings have been tightened, the next step is to turn the water supply back on and check for any leaks. It is important to carefully inspect the fittings and connections to ensure that there are no leaks. If any leaks are found, you may need to tighten the fittings further or reapply Teflon tape.

In conclusion, replacing the bypass valve on a Kenmore water softener is a relatively simple process that can be done with a few basic tools and materials. By following the steps outlined in this article, you can ensure that your water softener continues to operate efficiently and effectively. If you encounter any difficulties during the replacement process, it is always a good idea to consult the manufacturer’s instructions or seek the assistance of a professional plumber.

Category Type Feature Model Inlet/Outlet Drain Base Riser Pipe Brine Line Connector Water Capacity m3/h
Advanced Function Automatic Softener Valve Upflow Type\u00a0\u00a0 Dry Brine Tank ASE2 1/2″, 3/4″, 1″ 1/2″ 2.5″ 1.05″ OD 3/8″ 2
ASE4 3/4″, 1″ 1/2″ 2.5″ 1.05″ OD 3/8″ 4