Table of Contents
How to Properly Use the Kinetico Water Softener Bypass Valve
Water Softeners are essential appliances in many households, as they help to remove Minerals such as calcium and magnesium from hard water. One important feature of a water softener is the bypass valve, which allows you to temporarily bypass the softening process when needed. The Kinetico water softener bypass valve is a key component of the system, and knowing how to properly use it can help you maintain your water softener and ensure it functions effectively.
The bypass valve on a Kinetico water softener is typically located on the back of the unit, near the inlet and outlet connections. It is a simple valve that can be turned to either allow water to flow through the softener or bypass it completely. When the valve is in the “service” position, water flows through the softener, allowing it to remove minerals and soften the water. When the valve is in the “bypass” position, water flows around the softener, allowing it to bypass the softening process altogether.
There are several reasons why you may need to use the bypass valve on your Kinetico water softener. For example, if you need to perform maintenance on the softener, such as replacing the resin beads or cleaning the brine tank, you will want to bypass the softener to prevent water from flowing through it during the maintenance process. Additionally, if you are experiencing a leak or other issue with the softener, bypassing it can help prevent further damage while you address the problem.
Model | Central tube | Drain | Brine tank connector | Base | Power supply parameters | Maximum power | Pressure parameters | Operating temperature\u00a0 |
5600 | 0.8125″/1.050″ O.D. | 1/2″NPTF | 1600-3/8″ | 2-1/2″-8NPSM | 24v,110v,220v-50Hz,60Hz | 3W | 2.1MPa | 1\u2103-43\u2103 |
0.14-0.84MPa | ||||||||
5600SXT | 0.8125″/1.050″ O.D. | 1/2″NPTF | 1600-3/8″ | 2-1/2″-8NPSM | 24v,110v,220v-50Hz,60Hz | 8.4W | 2.1MPa | 1\u2103-43\u2103 |
0.14-0.84MPa | ||||||||
2510 | 1.05″ (1″)O.D. | 1/2″O.D. | 1600-3/8″ | 2-1/2″-8NPSM | 24v,110v,220v-50Hz,60Hz | 72W | 2.1MPa | 1\u2103-43\u2103 |
1650-3/8″ | 0.14-0.84MPa | |||||||
2700 | 1.05″ O.D. | 3/4″NPTF | 3/8″ & 1/2″ | 2-1/2″-8NPSM | 24V,110V,220V-50Hz,60Hz | 74W | 2.1MPa | 1\u2103-43\u2103 |
0.14-0.84MPa | ||||||||
2850 | 1.9″(1.5″)O.D. | 1″NPTM | 3/8″&1/2″ | 4″-8UN | 24v,110v,220v-50Hz,60Hz | 72W | 2.1MPa | 1\u2103-43\u2103 |
0.14-0.84MPa | ||||||||
2900 | 1.9″(1.5″)O.D. | 3/4″NPTM | 3/8″&1/2″ | 4″-8UN | 24v,110v,220v-50Hz,60Hz | 143W | 2.1MPa | 1\u2103-43\u2103 |
0.14-0.84MPa | ||||||||
3150 | 2.375″(2″) O.D. | 2″NPTF | 1″NPTM | 4″-8UN | 24v,110v,220v-50Hz,60Hz | 87W | 2.1MPa | 1\u2103-43\u2103 |
0.14-0.84MPa | ||||||||
3900 | 3.5″(3″) O.D. | 2″NPTF | 1″NPTM | 6″-8UN | 24v,110v,220v-50Hz,60Hz | 171W | 2.1MPa | 1\u2103-43\u2103 |
0.14-0.84MPa | ||||||||
9000 | 1.05″ O.D. | 1/2″NPT | 1600-3/8″ | 2-1/2″-8NPSM | 24v,110v,220v-50Hz,60Hz | 8.9W | 2.1MPa | 1\u2103-43\u2103 |
0.14-0.84MPa | ||||||||
9100 | 1.05″ O.D. | 1/2″NPT | 1600-3/8″ | 2-1/2″-8NPSM | 24v,110v,220v-50Hz,60Hz | 8.9W | 2.1MPa | 1\u2103-43\u2103 |
0.14-0.84MPa | ||||||||
9500 | 1.9″(1.5″) O.D. | 1″NPTF | 3/8″& 1/2″ | 4″-8UN | 24v,110v,220v-50Hz,60Hz | 8.9W | 2.1MPa | 1\u2103-43\u2103 |
0.14-0.84MPa |
To properly use the bypass valve on your Kinetico water softener, follow these steps:
1. Locate the bypass valve on the back of the unit. It is typically a lever or knob that can be turned to switch between the “service” and “bypass” positions.
2. To bypass the softener, turn the valve to the “bypass” position. This will allow water to flow around the softener, bypassing the softening process.
3. To return the softener to normal operation, turn the valve back to the “service” position. This will allow water to flow through the softener and be softened as usual.
In conclusion, the bypass valve on your Kinetico water softener is a valuable tool that allows you to temporarily bypass the softening process when needed. By following the steps outlined above, you can properly use the bypass valve to maintain your water softener and ensure it functions effectively. Remember to always return the softener to normal operation after bypassing it to ensure that your water remains soft and free of minerals.